The following standards are adopted and enforced: 

Code clarifications
Elevators and accessibility
Evacuation procedures
Illumination requirements
2005 Amendments
2003 Amendments

 
  • ASME A17.1 (2004)

  • ASME A17.2 (2001)

    • Inspector's Manual for Electric Elevators

  • ASME A17.3 (2002)

  • ASME A18.1 (2001)

    • Standard for wheelchir lifts and stairway chairlifts

  • ASME A90.1 (2001)

    • Standard for Belt Manlifts

  • Oregon Specialty Lift Code (Revised April 1, 2005)

    • Part 1 Verical Reciprocating Lifts (VRL). Governs the installation and operation of VRLs that are not part of a mechanized conveyor system.

    • Part 2 Portable Wheelchair Lift Code

 
Elevators and accessibility

The American with Disabilities Act (ADA) requires the installation of elevators in almost all new commerical buildings.

Chapters 11 and 30 of the Oregon Structural Specialty Code (OSSC) incorporate the ADA standards as prescribed in federal and state law (ref. to ORS Chapter 447). Architects and building planners must ensure that the building complies with ADA requirements of Chapter 11. When in doubt as to whether the building is required to be provided with an elevator, you should consult with the local building department.

While the Oregon Elevator Specialty Code does not regulate when elevators are required by Chapter 11 of the OSSC, it does regulate the installation of the elevator. ADA requirements for elevators are checked by the elevator program during plan review and also during site inspections.

 
Code clarifications

A17.1a 2002, Req. 2.7.3.4.4 (Oregon amendment)
Unobstructed Area in Front of Machine Room or Machinery Space Doors

 

Illumination requirements


ILLUMINATION REQUIREMENTS FOR PASSENGER & FREIGHT ELEVATORS

 

Location

Passenger

Freight

 

Pre-March
2003

As of March
2003

Pre-March
2003

As of March
2003

Pit Area

50 lx ( 5 ftc)

100 lx (10 ftc)

50 lx ( 5 ftc)

100 lx (10 ftc)

Machine Room

100 lx (10 ftc)

200 lx (19 ftc)

100 lx (10 ftc)

200 lx (19 ftc)

Inside Car

50 lx (5 ftc)

50 lx (5 ftc)

25 lx (2.5 ftc)

25 lx (2.5 ftc)

Emergency Light in Car

21 lx (0.2 ftc)

21 lx (0.2 ftc)

N/A

N/A

Corridor

50 lx (5 ftc)

100 lx (10 ftc)

50 lx (5 ftc)

100 lx (10 ftc)

lx = lux
ftc = foot-candles

 

General

While taking readings, avoid casting shadows on the meter or standing between the light source and the light meter. The following examples should help clarify how and where illumination levels are to be measured.

 


Pit Area

Pit lighting is to be measured at floor level and the meter should be directed toward the light source. Incident lighting can give lower readings than required.

 

 


Machine Rooms

Lighting in the elevator machine room is taken at floor level. The illumination should be as evenly distributed as possible over the floor area. Particular attention should be given to the illumination of controllers and machinery.

 


 

Inside Car

Illumination levels are to be measured at the threshold with the elevator doors closed.

 

 


Corridor

The area immediately outside the elevator entrance is to be properly illuminated. Readings are to be taken with the elevator doors closed.

 

 
2005 Amendments (Effective 4/1/05)

A17-1 Amendments 2005
A17-3 Amendments 2005
Code Effective Dates
OESC Portable Wheelchair Lift Code 2005
OESC VRL Code 2005
47-Rules Reprint
49-Rules Reprint
47-49 Rules - A17-3 Cross Reference

 
2003 Amendments (Effective 3/1/03 - for reference only after 4/1/05)

A17-1 Amendments 2003
A17-3 Amendments 2003
Code Effective Dates
OESC Portable Wheelchair Lift Code 2003
OESC VRL Code 2003
47-Rules Reprint
49-Rules Reprint
47-49 Rules - A17-3 Cross Reference

 
 
 

Get Adobe Acrobat ReaderAdobe Reader is required to view PDF files. Click the "Get Adobe Reader" image to get a free download of the reader from Adobe. Available for Macintosh or Windows.